DRDrySpace ResearchCrawl-space equipment research
Menu

Brand comparison

Moiswell vs AlorAir Crawl-Space Dehumidifiers

This page compares verified crawl-space dehumidifier records from Moiswell and AlorAir on a normalized basis. It does not declare a universal winner.

Research by Josiah Gavin

Current verified catalog

Moiswell models

AlorAir models

Normalized specification table

ManufacturerModelRated/AHAM PPDMaximum PPDManufacturer max coverageAirflowPumpOperating temperatureDimensionsWeightWarrantyVoltageIEFElectrical dataVerificationResearch
MoiswellAegis HP11053 pints/day120 pints/day4,500 sq ft180 CFMYes41-95 F21.8" L x 14" W x 14.9" H63.2 lb2-year full / 5-year limited110-120V, 60HzNot verifiedNot verified

2026-09-05

Product page
MoiswellDefender M7070 pints/day145 pints/day6,000 sq ft206 CFMNo41-95 F22.05" L x 14.56" W x 13.38" H61.2 lb2-year full / 5-year limited110-120V, 60HzNot verifiedNot verified

2026-09-05

Product page
MoiswellDefender MP7070 pints/day145 pints/day6,000 sq ft206 CFMYes41-95 F22.05" L x 14.56" W x 13.38" HNot verified2-year full / 5-year limited110-120V, 60Hz1.8 L/kWh at 65 F / 60% RHNot verified

2026-09-05

Verification note present

Product page
MoiswellAegis H15070 pints/day155 pints/day6,500 sq ft253 CFMNo41-95 F24.4" L x 14.6" W x 15.2" H65.2 lb2-year full / 5-year limited110-120V, 60HzNot verifiedNot verified

2026-09-05

Product page
MoiswellAegis HP15070 pints/day155 pints/day6,500 sq ft253 CFMYes41-95 F24.4" L x 14.6" W x 15.2" H65.2 lb2-year full / 5-year limited110-120V, 60Hz2.01 L/kWhNot verified

2026-09-05

Product page
AlorAirSentinel HD35P35 pints/day70 pints/day1,000 sq ft115 CFMYes33-105 F15.2" L x 11.2" W x 11.4" H38.18 lb6-year limited; first 2 years full coverage115V, 60HzNot verified334 W estimated

2026-09-05

Product page
AlorAirSentinel HD55S55 pints/day120 pints/day1,300 sq ft130 CFMNo33.8-104 F19.2" L x 12.2" W x 13.3" H41.7 lb6-year limited; first 2 years full coverage115VNot verified472 W estimated

2026-09-05

Product page
AlorAirSentinel HD55P55 pints/day120 pints/day1,300 sq ft153 CFMYesNot verifiedNot verifiedNot verifiedNot verifiedNot verifiedNot verifiedNot verified

2026-09-05

Verification note present

Product page
AlorAirSentinel HD9090 pints/day198 pints/day2,600 sq ft210 CFMNo33.8-104 F23.2" L x 15.2" W x 17.7" H67.2 lbNot verified115VNot verified639 W estimated

2026-09-05

Product page
AlorAirSentinel HDi9090 pints/day198 pints/day2,600 sq ft210 CFMYes33.8-104 F23.2" L x 15.2" W x 17.7" H70.5 lb6-year limited; first 2 years full coverage115VNot verified639 W estimated

2026-09-05

Product page
AlorAirHelios D3535 pints/day70 pints/day1,000 sq ft97 CFMNo37.4-100.4 F16.4" L x 11.25" W x 10.76" H25.13 lbNot verified115V, 60HzNot verifiedNot verified

2026-09-08

Verification note present

Product page
AlorAirGalaxy 6060 pints/day145 pints/day1,800 sq ft165 CFMNo37.4-100.4 F21.3" L x 11.7" W x 14.1" H47.5 lbNot verified115V, 60HzNot verified518 W estimated

2026-09-08

Verification note present

Product page
AlorAirGalaxy 60P60 pints/day145 pints/day1,800 sq ft165 CFMYes37.4-100.4 F21.3" L x 11.7" W x 14.15" H47.5 lbNot verifiedNot verifiedNot verifiedNot verified

2026-09-08

Verification note present

Product page
AlorAirGalaxy 85P85 pints/day180 pints/day2,300 sq ft194 CFMYes37.4-100.4 F21.3" L x 11.7" W x 14.1" H57.3 lbNot verified115V, 60HzNot verified610 W estimated

2026-09-08

Verification note present

Product page
AlorAirSentinel HDi100100 pints/day220 pints/day2,900 sq ft250 CFMYes33.8-104 F23.8" L x 14.7" W x 17.9" H88 lb1-year limited parts and labor; 3-year limited coil; 5-year limited compressor115V, 60HzNot verified784 W estimated

2026-09-08

Verification note present

Product page
AprilAireE05050 pints/dayNot verified1,600 sq ft145 CFMNo50-104 F9.86" H x 9.71" W x 25" D46 lb6-year warranty: 5-year full replacement plus 1-year parts115V, 60HzNot verified483 W estimated

2026-09-08

Verification note present

Product page
AprilAireE07070 pints/dayNot verified2,200 sq ft200 CFMNo50-104 F12.5" H x 12.5" W x 25" D56 lbNot verified110-120V, 60HzNot verified756 W estimated

2026-09-08

Verification note present

Product page
AprilAireE08080 pints/dayNot verified4,400 sq ft185 CFMNo50-104 F15" H x 14" W x 26" D63 lbNot verified110-120V, 60HzNot verified612 W estimated

2026-09-08

Verification note present

Product page
AprilAireE100100 pints/dayNot verified5,500 sq ft280 CFMNo50-104 F15" H x 14" W x 26" D64 lbNot verified110-120V, 60HzNot verified828 W estimated

2026-09-08

Verification note present

Product page
AprilAireE130130 pints/dayNot verified7,200 sq ft310 CFMNo50-104 F18.75" H x 19.5" W x 30" D98 lbNot verified110-120V, 60HzNot verified996 W estimated

2026-09-08

Verification note present

Product page
ArgendonShield 35M35 pints/day70 pints/day1,000 sq ft115 CFMNo33-105 F15.35" L x 11.2" W x 11.4" H37.8 lbNot verified115V, 60HzNot verified334 W estimated

2026-09-09

Verification note present

Product page
ArgendonShield 35P35 pints/day70 pints/day1,000 sq ft115 CFMYes33-105 F15.2" L x 11.2" W x 11.4" H38.18 lbNot verified115V, 60HzNot verified334 W estimated

2026-09-09

Verification note present

Product page
ArgendonSandidry 55C55 pints/day120 pints/day1,300 sq ft153 CFMYes33-105 F17.64" L x 11.69" W x 11.85" H44.53 lbNot verified115V, 60HzNot verified404 W estimated

2026-09-09

Verification note present

Product page
ArgendonShield 6060 pints/day145 pints/day1,800 sq ft185 CFMNo35.6-102.2 F21.3" L x 12.8" W x 14.6" H46.5 lbNot verified115V, 60HzNot verified474 W estimated

2026-09-09

Verification note present

Product page
ArgendonShield 60P60 pints/day145 pints/day1,800 sq ft165 CFMYes35.6-102.2 F21.3 x 14.1 x 11.7 in46.5 lbNot verified115V, 60HzNot verified474 W estimated

2026-09-09

Verification note present

Product page
ArgendonShield 85P85 pints/day180 pints/day2,300 sq ft194 CFMYes35.6-102.2 F21.3" L x 12.8" W x 14.6" H55.8 lbNot verified115V, 60HzNot verified647 W estimated

2026-09-09

Verification note present

Product page

Matched comparison examples

DrySpace does not force every product into a one-to-one pairing. The current cross-brand focused page compares two pump-equipped models with relatively close AHAM capacity.

Data-quality notes

How DrySpace handles incomplete data

DrySpace uses manufacturer documentation and official sources already represented in the product database. Verification dates are recorded, unknown fields stay marked as not verified, and conflicting manufacturer values are surfaced rather than resolved by guessing.

Current conflict examples

  • Moiswell Defender MP70: Weight is not populated because current official Moiswell pages conflict: one page reports 70 lb while another current comparison page reports 61.2 lb.
  • AlorAir Sentinel HD55P: Operating current and estimated power draw are not populated because the current official AlorAir spec sheet conflicts internally, listing both 3.51 A and 3.1 A.
  • AlorAir Helios D35: Operating current and estimated power draw are not populated because the reviewed current first-party sources did not provide an operating-current value for this model. Warranty is not populated because the product page's 6-year marketing warranty language and the manual's staged warranty coverage are not identical.
  • AlorAir Galaxy 60: The current product page lists the height as 14.15 in, while the current specification sheet lists 14.1 in. DrySpace stores the specification-sheet dimension. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the reviewed first-party sources did not provide a single unambiguous warranty statement matching the existing DrySpace warranty-summary style.
  • AlorAir Galaxy 60P: Operating current, voltage, frequency, sound level, and estimated power draw are not populated because the reviewed current first-party sources did not provide verified values for this specific model. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the reviewed first-party sources did not provide a single unambiguous warranty statement matching the existing DrySpace warranty-summary style.
  • AlorAir Galaxy 85P: The current product page lists the height as 14.15 in, while the current specification sheet lists 14.1 in. DrySpace stores the specification-sheet dimension. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the reviewed first-party sources did not provide a single unambiguous warranty statement matching the existing DrySpace warranty-summary style.
  • AlorAir Sentinel HDi100: Current first-party sources conflict on AHAM capacity: the current specification sheet and product-page feature copy list 100 PPD at AHAM, while the product-page specification table lists 120 PPD at AHAM. DrySpace stores the current specification-sheet value. Current first-party sources conflict on airflow: the current specification sheet lists 250 CFM, while the product-page specification table lists 250 CMH. DrySpace stores the current specification-sheet value. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. The product page also uses broader 6-year warranty copy; DrySpace stores the more specific warranty block shown on the same current product page.
  • AprilAire E050: The 50 pints/day capacity is stored as rated capacity, not AHAM, because the reviewed E050 sources did not label it as AHAM. Energy factor values from the specification sheet are not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from energy factor.
  • AprilAire E070: AprilAire current sources conflict for the E070: the current AprilAire FAQ lists 6.3 A, while older mirrored installation instructions list lower operating-current values. DrySpace stores the current FAQ value and notes the conflict. No AprilAire maximum/saturation PPD value was found, so maximum removal is intentionally unknown.
  • AprilAire E080: The 80 pints/day capacity is stored as rated capacity, not AHAM, because the reviewed E080 sources did not label it as AHAM. No AprilAire maximum/saturation PPD value was found, so maximum removal is intentionally unknown. Energy factor values from the specification sheet are not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from energy factor.
  • AprilAire E100: The 100 pints/day capacity is stored as rated capacity, not AHAM, because the reviewed E100 sources did not label it as AHAM. AprilAire current sources conflict for the E100: the current AprilAire FAQ and E080/E100 installation-guide mirror list 6.9 A, while a mirrored E100 specification sheet lists 6.7 A. DrySpace stores the FAQ/manual value and notes the conflict. No AprilAire maximum/saturation PPD value was found, so maximum removal is intentionally unknown. Energy factor values from the specification sheet are not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from energy factor.
  • AprilAire E130: The 130 pints/day capacity is stored as rated capacity, not AHAM, because the reviewed E130 sources did not label it as AHAM. No AprilAire maximum/saturation PPD value was found, so maximum removal is intentionally unknown. Energy factor values from the specification sheet are not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from energy factor.
  • Argendon Shield 35M: The current product page lists sound level as 50 dBA, while the current specification sheet lists < 50 dBA. DrySpace stores the product-page table value. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the product page uses limited 5-year warranty marketing copy that was not normalized into a formal warranty summary.
  • Argendon Shield 35P: The current product page lists dimensions as 15.2 x 11.2 x 11.4 in and unit weight as 38.18 lb, while the current specification sheet lists 15.35 x 11.2 x 11.4 in and 39.7 lb. DrySpace stores the product-page table values. The current product page lists sound level as 50 dBA, while the current specification sheet lists < 50 dBA. DrySpace stores the product-page table value. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the product page uses limited 5-year warranty marketing copy that was not normalized into a formal warranty summary.
  • Argendon Sandidry 55C: Current first-party sources conflict on coverage: the product page lists 1,300 sq ft, while the current specification sheet lists up to 1,500 sq ft. DrySpace stores the current product-page coverage claim. The current product page lists unit weight as 44.53 lb and sound level as 57 dBA, while the current specification sheet lists 44.4 lb and < 57 dBA. DrySpace stores the product-page table values. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the product page uses limited 5-year warranty marketing copy that was not normalized into a formal warranty summary.
  • Argendon Shield 60: Current first-party sources conflict on coverage: the product page lists 1,800 sq ft, while the current specification sheet lists up to 1,500 sq ft. DrySpace stores the current product-page coverage claim. Drainage is stored as gravity drainage with no built-in pump because the product page is a no-pump listing and provides only a gravity drain hose length, despite table wording of 'Gravity pump' and specification-sheet wording of 'Auto Drain'. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the product page uses limited 5-year warranty marketing copy that was not normalized into a formal warranty summary.
  • Argendon Shield 60P: No separate Shield 60P specification-sheet link was found on the current product page, so DrySpace stores the current product-page specification table with the first-party user manual as supporting documentation. COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the product page uses limited 5-year warranty marketing copy that was not normalized into a formal warranty summary.
  • Argendon Shield 85P: COP is not stored in the Integrated Energy Factor field because DrySpace tracks IEF separately from manufacturer COP/efficiency claims. Warranty is not populated because the product page uses limited 5-year warranty marketing copy that was not normalized into a formal warranty summary.